Output Component
Each platform of the output domain exposes some output to
ESPHome. These are grouped into two categories: binary outputs
(that can only be ON/OFF) and float outputs (like PWM, can output
any rational value between 0 and 1).
Base Output Configuration
Each output platform extends this configuration schema.
# Example configuration entry
output:
- platform: ...
id: my_output_id
power_supply: power_supply_id
inverted: false
min_power: 0.01
max_power: 0.75Configuration variables:
id (Required, ID): The id to use for this output component.
power_supply (Optional, ID): The power supply to connect to this output. When the output is enabled, the power supply will automatically be switched on too.
inverted (Optional, boolean): If the output should be treated as inverted. Defaults to
false.
Float outputs only:
min_power (Optional, float): Sets the minimum output value of this output platform. Must be in range from 0 to max_power. Defaults to
0. If zero_means_zero isfalsethis will be output value when the entity is turned off.max_power (Optional, float): Sets the maximum output value of this output platform. Must be in range from min_power to 1. Defaults to
1.zero_means_zero (Optional, boolean): Sets the output to use actual 0 instead of
min_power. Defaults tofalse.
ℹ️ Note
The
min_powerandmax_powervalues are automatically clamped to ensure0.0 ≤ min_power ≤ max_power ≤ 1.0. This prevents invalid configurations and ensures stable output behavior.
output.turn_on Action
This action turns the output with the given ID on when executed.
on_...:
then:
- output.turn_on: light_1ℹ️ Note
This action can also be expressed in lambdas:
id(light_1).turn_on();
output.turn_off Action
This action turns the output with the given ID off when executed.
on_...:
then:
- output.turn_off: light_1ℹ️ Note
This action can also be expressed in lambdas:
id(light_1).turn_off();
output.set_level Action
This action sets the float output to the given level when executed.
ℹ️ Note
This only works with floating point outputs like AC Dimmer Component, ESP8266 Software PWM Output, ESP32 LEDC Output, Sigma-Delta Output, Slow PWM Output.
on_...:
then:
- output.set_level:
id: light_1
level: 50%ℹ️ Note
This action can also be expressed in lambdas:
// range is 0.0 (off) to 1.0 (on) id(light_1).set_level(0.5);
output.set_min_power Action
This action sets the minimum output power level for the specified float output platform.
It allows you to dynamically adjust the min_power configuration variable at runtime.
ℹ️ Note
This only works with floating point outputs like AC Dimmer Component, ESP8266 Software PWM Output, ESP32 LEDC Output, Sigma-Delta Output, Slow PWM Output.
on_...:
then:
- output.set_min_power:
id: light_1
min_power: 20%ℹ️ Note
This action can also be expressed in lambdas:
// range is 0.0 (off) to 1.0 (on) id(light_1).set_min_power(0.2);
output.set_max_power Action
This action sets the maximum output power level for the specified float output platform.
It allows you to dynamically adjust the max_power configuration variable at runtime.
ℹ️ Note
This only works with floating point outputs like AC Dimmer Component, ESP8266 Software PWM Output, ESP32 LEDC Output, Sigma-Delta Output, Slow PWM Output.
on_...:
then:
- output.set_max_power:
id: light_1
max_power: 80%ℹ️ Note
This action can also be expressed in lambdas:
// range is 0.0 (off) to 1.0 (on) id(light_1).set_max_power(0.8);